| Machine
Products --> Pumping
Systems --> RPV Volumetric Resin Delivery
System Machine
Products:
RPV Volumetric
Resin Delivery System
The quality of your
sand is only as good as the accuracy of your Resin
Delivery System
- The RPV ELIMINATES
Inaccurate, Inconsistent Resin Delivery
- The RPV ELIMINATES
the Need for Constant Re-Calibration
- The RPV ELIMINATES
High Parts Replacement Costs
Shipped 100% Tested,
Assembled, and Ready to Install
General
The Palmer Retrofit
Volumetric Resin Delivery System is a completely
self contained unit to eliminate the problems
associated with old, worn, poorly designed systems
that cause such problems as inaccurate delivery,
inconsistent delivery, resin bleed back, the need
for constant re-calibration, and high replacement
parts cost. The Palmer RPV is particularly helpful
when used to replace resin delivery systems designed
around high RPM, low displacement pumps or
complicated calibration control systems.
The entire RPV System
is housed in a NEMA enclosure which can be mounted
on or near the existing mixer. All electrical
controls are housed in a smaller NEMA 12 enclosure,
located within the larger enclosure for added
protection. All necessary controls are accessible
through a window on the door of the large enclosure.
This design allows
easy access to all controls, switches, pumps, and
drives, while protecting them from dust, sand, and
accidental damage.
Electrical
The electrical
control system features two modes of operation.
The first is HAND, or
manual mode, in which the filling and discharge of
each resin reservoir is controlled manually by the
operator.
The second mode is
AUTOMATIC, in which all aspects of the RPV operate
based on a trigger signal from the electrical
control system of the existing batch mixer.
The trigger signal is
the only electrical connection required between the
existing mixer and the RP.
High tolerance liquid
level detection proximity switches provide for an
adjustable resin amount within the resin reservoir.
System controls are
managed by a state of the art smart relay system.
This system offers the flexibility and power of a
PLC at a fraction of the price.
Plumbing
The RPV features, as
standard, two appropriately sized resin reservoirs.
Each reservoir has an inlet and discharge air
actuated stainless steel ball valve. The inlet valve
prevents resin from bleeding back once the reservoir
is filled while the discharge valve prevents seepage
while filling the reservoirs.
The pneumatic system
is separated into two parts. The first is the
manifold which controls the air actuated ball
valves. This operates off of plant compressed air.
The second manifold
is used for the injection of resin into the mixer.
The purpose of the separation is to allow the user
to determine the transfer gas for the resins; the
user can utilize either plant compressed air or
inert gas for this function.
Discharge pressure of
each reservoir is adjustable.
Order of Operation
- Previous cycle
completes.
- Inlet ball valve
opens and reservoirs are either gravity fed or
pump fed via control signal
- Top liquid level
proximity switch is covered
- Inlet valve closes
- Unit awaits
discharge signal from mixer
- Upon signal,
reservoir one empties to bottom liquid level
proximity switch
- A wait timer
engages prior to discharging reservoir two
- Reservoir two
discharges to bottom proximity switch
- Unit refills
Options
- All units are
sized based on batch mixer resin requirements
- Acid system
upgrade
- Multiple resin
levels
- Batch mixer
controls integration
|